2210_TK-05

AG LE H Series High Performance, Low Energy, High Rejection Brackish Water RO Membrane

The AG LE H Series of thin-film reverse osmosis (RO) membranes are designed to perform in brackish water applications where the customer and application seek to balance low energy and high rejection requirements. AG LE H Series membranes optimize SUEZ chemistry and manufacturing advancements to deliver differentiated performance over the life of the element. In contrast to ultra-low energy AK H Series, the AG LE H Series membranes are often used with the need to control flux due to increased risk of fouling such as when a surface water source is used.

All AG LE H Series membranes have NSF 61 certification.

Part Number

Part Number 3187569 AG LE H Series High Performance, Low Energy, High Rejection Brackish Water RO Elements, AG-400 LE H
3187650 AG LE H Series High Performance, Low Energy, High Rejection Brackish Water RO Elements, AG-440 LE H

Element Specification

Model Average permeate

flow gpd (m³/day) (1)(2)

Typical NaCl rejection (1,2) Minimum NaCl rejection (1,2)
AG-400 LE H 10,000 (37.9) 99.5% 99.0%
AG-440 LE H 11,000 (41.6) 99.5% 99.0%

(1) Average salt rejection after 24 hours of operation. Individual flow rate may vary ±20%.
(2) Testing conditions: 2,000 ppm NaCl solution at 150 psi (1,034 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery.

Model Active area ft² (m²) Outer wrap Feed Spacer (mil) Part

number

AG-400 LE H 400 (37.2) Fiberglass 34 3187569
AG-440 LE H 440 (40.9) Fiberglass 28 3187650

 

Operating & CIP Parameters

Typical Operating Pressure 150 psi (1,034 kPa)
Typical Operating Flux 10-20 GFD (15-35 LMH)
Maximum Operating Pressure 600 psi (4,137 kPa)
Maximum Temperature Continuous operation: 122°F (50°C)

Clean-In-Place (CIP): 122°F (50°C)

pH range Optimum rejection: 7.0-7.5

Continuous operation 2.0-11.0

Clean-In-Place (CIP): 1.0-12.0 (1)

Maximum Pressure Drop Over an element: 15 psi (103 kPa)

Per housing: 50 psi (345 kPa)

Chlorine Tolerance 1,000+ ppm-hours, dechlorination recommended
Feedwater NTU < 1

SDI15 < 5

(1) Please refer to Cleaning Guidelines Technical Bulletin TB1194

Fact Sheet

Download Fact Sheet

Enquiries

Get in touch with us! We’re here to help you find the solution that best resolves your challenges around water filtration. 

Product Enquiries

Get in touch with us! We’re here to help you find the solution that best resolves your challenges around water filtration.