Element Specification
Model |
Average permeate
flow gpd (m³/day) (1)(2) |
Average NaCl rejection (1,2) |
Minimum NaCl rejection (1,2) |
AG-90 |
2400 (9.1) |
99.8% |
99.3% |
AG-365 |
10,000 (37.9) |
99.8% |
99.3% |
AG-400 |
11,000 (41.6) |
99.8% |
99.3% |
AG-400,34 |
11,000 (41.6) |
99.8% |
99.3% |
AG-440 |
12,000 (45.4) |
99.8% |
99.3% |
(1) Average salt rejection after 24 hours operation. Individual flow rate may vary ±20%.
(2) Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating pressure, 77°F (25°C), pH7 and 15% recovery.
Model |
Active area ft² (m²) |
Outer wrap |
Part number |
AG-90 |
90 (8.4) |
Fiberglass |
3056665 |
AG-365 |
365 (33.9) |
Fiberglass |
3056666 |
AG-400 |
400 (37.2) |
Fiberglass |
3056667 |
AG-400,34 |
400 (37.2) |
Fiberglass |
3056668 |
AG-440 |
440 (40.9) |
Fiberglass |
3056669 |
Operating & CIP Parameters
Typical Operating Pressure |
200 psi (1,380 kPa) |
Typical Operating Flux |
10-20GFD (15-35LMH) |
Maximum Operating Pressure |
600 psi (4,137 kPa) |
Maximum Temperature |
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C) |
pH range |
Optimum rejection: 7.0-7.5,
Continuous operation 2.0 – 11.0
Clean-In-Place (CIP): 1.0-13.0 (1) |
Maximum Pressure Drop |
Over an element: 15 psi (103 kPa)
Per housing: 50 psi (345 kPa) |
Chlorine Tolerance |
1,000+ ppm-hours, dechlorination recommended |
Feedwater |
NTU < 1
SDI15 < 5 |
(1) Refer to Cleaning Guidelines Technical Bulletin TB1194