2210_TK-05

AG H Series High Performance, Very High Rejection Brackish Water RO Membrane

The AG H Series of thin-film reverse osmosis (RO) membranes are designed to perform in brackish water applications where the very highest levels of rejection are needed. AG H Series membranes combine SUEZ chemistry and manufacturing advancements to deliver differentiated performance over the life of the element in ionic rejection and in the rejection of uncharged or lightly charged species such as silica. These membranes are ideal for applications such as ultrapure water production, treating high pressure boiler feed water, or any other application when the very highest rejection is needed.

All AG H Series membranes have NSF 61 certification

Part Number

Part Number 3056665 AG HR Series High rejection Brackish Water RO Elements, AG-90
3056666 AG HR Series High rejection Brackish Water RO Elements, AG-365
3056667 AG HR Series High rejection Brackish Water RO Elements, AG-400
3056668 AG HR Series High rejection Brackish Water RO Elements, AG-400,34
3056669 AG HR Series High rejection Brackish Water RO Elements, AG-440

Element Specification

Model Average permeate

flow gpd (m³/day) (1)(2)

Typical NaCl rejection (1,2) Minimum NaCl rejection (1,2)
AG-400 H 11,000 (41.6) 99.8% 99.65%
AG-440 H 12,000 (45.4) 99.8% 99.65%

(1) Average salt rejection after 24 hours of operation. Individual flow rate may vary ±20%.
(2) Testing conditions: 2,000 ppm NaCl solution at 225 psi (1,550 kPa) operating pressure, 77°F (25°C), pH 7 and 15% recovery.

Model Active area ft² (m²) Outer wrap Feed Spacer (mil) Part

number

AG-400 H 400 (37.2) Fiberglass 34 3150329
AG-440 H 440 (40.9) Fiberglass 28 3150328

Operating & CIP Parameters

Typical Operating Pressure 200 psi (1,380 kPa)
Typical Operating Flux 10-20 GFD (15-35 LMH)
Maximum Operating Pressure 600 psi (4,137 kPa)
Maximum Temperature Continuous operation: 122°F (50°C)

Clean-In-Place (CIP): 122°F (50°C)

pH range Optimum rejection: 7.0-7.5

Continuous operation 2.0-11.0

Clean-In-Place (CIP): 1.0-12.0 (1)

Maximum Pressure Drop Over an element: 15 psi (103 kPa)

Per housing: 50 psi (345 kPa)

Chlorine Tolerance 1,000+ ppm-hours, dechlorination recommended
Feedwater NTU < 1

SDI15 < 5

(1) Please refer to Cleaning Guidelines Technical Bulletin TB1194

Fact Sheet

Download Fact Sheet

Enquiries

Get in touch with us! We’re here to help you find the solution that best resolves your challenges around water filtration. 

Product Enquiries

Get in touch with us! We’re here to help you find the solution that best resolves your challenges around water filtration.